I. Solution Overview
Chenfeng Lingchuang is committed to providing efficient and reliable automatic fire suppression solutions for wind turbine generators. Among the most commonly adopted configurations in the industry are the 3 kg thermal aerosol automatic fire suppression system and miniature thermal aerosol fire suppression devices equipped with temperature-sensing magnetic power-generation actuators.
These solutions fully comply with applicable domestic fire protection regulations and offer advantages such as simple operation, high reliability, and strong adaptability to complex operating environments, effectively ensuring the fire safety of wind turbine generators.
II. Solution Details
1. 3 kg Thermal Aerosol Automatic Fire Suppression System

Model: QRR3GW/S-CFLC
(1) Technical Features
Designed in accordance with the structural characteristics and operating conditions of wind turbines
No routine inspection required, easy to operate
Utilizes a passive self-activating detection cable, distributed around the top perimeter of the nacelle, as well as at key fire-risk areas such as the generator and gearbox tops
All thermal aerosol fire suppression devices are connected in series
Equipped with a mechanical temperature-sensing magnetic power-generation actuator
Automatic activation at 93 °C, with passive dry-contact feedback signal output after discharge
(2) Installation Locations

Suspended on both sides of the nacelle
Inside nacelle control cabinets
Inside frequency converter cabinets
Above the cables at the bottom of the generator
(3) System Configuration List
| No. | Product Name | Model | Function | Installation Notes |
|---|---|---|---|---|
| 1 | 3 kg Thermal Aerosol Fire Suppression Device | QRR3GW/S-CFLC | Fire suppression | Installed inside the nacelle |
| 2 | Temperature-Sensing Magnetic Power-Generation Actuator | CF-CFD-01-93/110 | Activation device | Installed adjacent to the suppression unit |
2. Miniature Thermal Aerosol Fire Suppression Device

Model: QRR0.1GW/S-CFLC
(1) Technical Features
Activation temperature: 170 °C ±20 °C
Operating temperature range: –50 °C to +90 °C
Protected volume: 0.8–1.0 m³
Service life: 10 years
Activation via temperature-sensitive thermal detection wire or open flame
Suitable for applications with lower system complexity requirements
(2) Installation Scheme
Nacelle control cabinet: Two units installed at the top, focusing on low-voltage terminal monitoring
Tower base control cabinet: Two units installed, with detection wires arranged near circuit breaker busbars and power cables
Frequency converter cabinet: Two units installed, with detection wires arranged near power units and control boards
(3) System Configuration (Per Turbine)
| No. | Product Name | Model | Function | Remarks |
|---|---|---|---|---|
| 1 | Thermal Aerosol Automatic Fire Suppression Device | QRR0.1GW/S-CFLC | Fire suppression | Suitable for switchgear, frequency converter cabinets, and tower base control cabinets |
3. Thermal Aerosol Automatic Fire Suppression Device


Model: QRR0.25GW/S-CFLC
(1) Technical Features
Activation temperature: 170 °C ±20 °C
Operating temperature range: –50 °C to +90 °C
Protected volume: 2.0–2.5 m³
Service life: 10 years
Activation via temperature-sensitive thermal detection wire or open flame
Can be integrated with a detection backend monitoring system
(2) Installation Scheme
Nacelle control cabinet: One unit
Tower base control cabinet and frequency converter cabinet: Two units installed at the top of each cabinet
(3) System Configuration (Per Turbine)
| No. | Product Name | Model | Function | Remarks |
|---|---|---|---|---|
| 1 | Thermal Aerosol Automatic Fire Suppression Device | QRR0.25GW/S-CFLC | Fire suppression | Nacelle control cabinet, frequency converter cabinet, tower base control cabinet |
| 2 | Temperature-Sensing Magnetic Power-Generation Actuator | CF-CFD-01-93/110 | Activation device | Installed adjacent to the suppression unit |

III. Advantages of the Solution
Highly Specialized Design
Customized configurations for different wind turbine types, covering all critical fire-risk areas.Safe and Reliable
Compliant with domestic fire protection regulations, featuring sensitive activation and effective fire suppression performance.Low Maintenance Requirements
Certain configurations require no routine maintenance, significantly reducing operational costs.Wide Environmental Adaptability
Designed for wide temperature ranges, suitable for wind farms in diverse geographic and climatic conditions.